FLOW PRODUCTS

Metron AS markets sells and services automation equipment and field instruments. This includes agency operations for reputable products from manufacturers with worldwide distribution networks.

Magnetic Inductive Flowmeter (Flow Meter) – All Metal – Stainless Steel – MIM

Measuring range: 0.03 – 3 l/min … 1.5 – 350 l/min liquids
Accuracy: ±(0.8% of reading + 0.5% of FS)
pmax: 16 bar
tmax: +140°C
Connection: G ½, G ¾, G 1, G 2, 2″ NPT
Material: stainless steel, PEEK
Output: 2x analogue, pulse, frequency, alarm or IO-Link
Input: 1x control input
Options/Features:
integrated PT1000, dosing function, rotatable TFT display, bidirectional measurement, part- and grand totalizer, stainless steel design, usable even with hand gloves

Magnetic Inductive Flowmeter/-monitor MIK For conductivity liquids

Measuring range: 0.01 – 0.5 … 35 – 700 l/min liquid
Connection: G ½ … G 2 ¾ male thread
Material: PPS/stainless steel, PVDF/Hastelloy® , tantalum
pmax: 10 bar
tmax: 80°C
Accuracy: ±2 % of full scale
Switchpoint, frequency or analogue output,
LED-Indication with 2 open collectors or 4 – 20 mA/1 open collector, counter, batcher

Vortex Flowmeter – Counter DVZ-..E

Measuring range: 0.5 – 4.5 … 10 – 100 l/min water
Connection: G ¼ … G 1, ¼ … 1″ NPT
Material: connection: brass, stainless steel, housing: PPS
pmax: 20 bar
tmax: 80°C
Accuracy: ±2.5 % of full scale
Analogue output, counter, contacts, digital indicator

Oval Wheel Flowmeter DON-H
For low and high viscous liquids, high pressure

Measuring range: 0.5 – 36 l/h … 1-40 l/min liquid
Viscosity range: 0 – 1000 cP
Connection: G ⅛ … G ½, ⅛» NPT … ½» NPT female thread
Material: stainless steel
pmax: 400 bar
tmax: 120°C
Accuracy: ±0.2 … 1 % of reading
Pulse output, analogue output, contacts,
digital / pointer indicator, batcher

flow-captor 4220.xxf/.xxtm xx° c

flow-sensor with analogue display and additional temperature
output in a rugged stainless steel housing (full encapsulation)
for monitoring flow and temperature of water-based media

Operating principle: calorimetric (thermal)
Measuring range: 0 – 20 cm/s to 0 – 300 cm/s, continuously adjustable
Medium temperature: -20 °C to +80 °C / -4 °F to +176 °F
Set-point temperature: 50 °C, 70 °C, 80 °C / 122 °F, 158 °F, 176 °F
(other set-points on request)
Supply voltage: 18 – 30 VDC

low captor 4120.30 i-captor

Insertion flow meter for water- and oil-based media

Analog current and temperature output

The i-captor includes standard features such as highly accurate temperature sensing and is available with both 4-20mA outputs for temperature and flow as well as RS485 Modbus RTU for digital signalling. 

The i-captor is simple, easy to install, very affordable and inherits weber’s legendary reliability. It does not suffer from accuracy losses due to changes in fluid temperature, has a better than 2% accuracy over range with better than 2% repeatability.

It is the ideal choice for most water monitoring jobs from large chilled water systems with up to 20” pipes to just about any process need.

vent-captor 3302.1x/xx

Inline flow-switch for monitoring air and other gaseous media

especially suited to small bore application, virtually non invasive, minimal flow constriction, small footprint

Output: switched transistor, fully adjustable switch point
Operating principle: calorimetric (thermal mass)
Measuring range: 0.5 to 20 m/s (switch point adjustment)
Options:  factory calibration, enclosures
Pipe options (OD): 8 – 28 mm diameter, stainless steel
Supply voltage: 18 – 30 VDC, other options on request

 

vent-captor 3202.3x/xx

flow meter for air and other gases

3202.30/xx:current output (4 – 20 mA)
3202.31/xx: voltage output (0.1 – 10 V)

Operating principle: calorimetric (thermal mass)
Measuring range: 0 – 5 m/s to 0 – 50 m/s, fully adjustable
Options: high temperature (3205.30)
Supply voltage: 18 – 30 VDC

 

 