Flow

Metron AS markedsfører, selger automatiseringsutstyr og feltinstrumenter. Dette inkluderer byråvirksomhet for anerkjente produkter fra produsenter med verdensomspennende distribusjonsnett.

Magnetic Inductive Flowmeter (Flow Meter) – All Metal – Stainless Steel – MIM

Measuring range: 0.03 – 3 l/min … 1.5 – 350 l/min liquids
Accuracy: ±(0.8% of reading + 0.5% of FS)
pmax: 16 bar
tmax: +140°C
Connection: G ½, G ¾, G 1, G 2, 2″ NPT
Material: stainless steel, PEEK
Output: 2x analogue, pulse, frequency, alarm or IO-Link
Input: 1x control input
Options/Features:
integrated PT1000, dosing function, rotatable TFT display, bidirectional measurement, part- and grand totalizer, stainless steel design, usable even with hand gloves

Magnetic Inductive Flowmeter/-monitor MIK For conductivity liquids

Measuring range: 0.01 – 0.5 … 35 – 700 l/min liquid
Connection: G ½ … G 2 ¾ male thread
Material: PPS/stainless steel, PVDF/Hastelloy® , tantalum
pmax: 10 bar
tmax: 80°C
Accuracy: ±2 % of full scale
Switchpoint, frequency or analogue output,
LED-Indication with 2 open collectors or 4 – 20 mA/1 open collector, counter, batcher

Vortex Flowmeter – Counter DVZ-..E

Measuring range: 0.5 – 4.5 … 10 – 100 l/min water
Connection: G ¼ … G 1, ¼ … 1″ NPT
Material: connection: brass, stainless steel, housing: PPS
pmax: 20 bar
tmax: 80°C
Accuracy: ±2.5 % of full scale
Analogue output, counter, contacts, digital indicator

Oval Wheel Flowmeter DON-H
For low and high viscous liquids, high pressure

Measuring range: 0.5 – 36 l/h … 1-40 l/min liquid
Viscosity range: 0 – 1000 cP
Connection: G ⅛ … G ½, ⅛” NPT … ½” NPT female thread
Material: stainless steel
pmax: 400 bar
tmax: 120°C
Accuracy: ±0.2 … 1 % of reading
Pulse output, analogue output, contacts,
digital / pointer indicator, batcher

flow-captor 4220.xxf/.xxtm xx° c

flow-sensor with analogue display and additional temperature
output in a rugged stainless steel housing (full encapsulation)
for monitoring flow and temperature of water-based media

Operating principle: calorimetric (thermal)
Measuring range: 0 – 20 cm/s to 0 – 300 cm/s, continuously adjustable
Medium temperature: -20 °C to +80 °C / -4 °F to +176 °F
Set-point temperature: 50 °C, 70 °C, 80 °C / 122 °F, 158 °F, 176 °F
(other set-points on request)
Supply voltage: 18 – 30 VDC

low captor 4120.30 i-captor

Insertion flow meter for water- and oil-based media

Analog current and temperature output

The i-captor includes standard features such as highly accurate temperature sensing and is available with both 4-20mA outputs for temperature and flow as well as RS485 Modbus RTU for digital signalling. 

The i-captor is simple, easy to install, very affordable and inherits weber’s legendary reliability. It does not suffer from accuracy losses due to changes in fluid temperature, has a better than 2% accuracy over range with better than 2% repeatability.

It is the ideal choice for most water monitoring jobs from large chilled water systems with up to 20” pipes to just about any process need.

vent-captor 3302.1x/xx

Inline flow-switch for monitoring air and other gaseous media

especially suited to small bore application, virtually non invasive, minimal flow constriction, small footprint

Output: switched transistor, fully adjustable switch point
Operating principle: calorimetric (thermal mass)
Measuring range: 0.5 to 20 m/s (switch point adjustment)
Options:  factory calibration, enclosures
Pipe options (OD): 8 – 28 mm diameter, stainless steel
Supply voltage: 18 – 30 VDC, other options on request

 

vent-captor 3202.3x/xx

flow meter for air and other gases

3202.30/xx:current output (4 – 20 mA)
3202.31/xx: voltage output (0.1 – 10 V)

Operating principle: calorimetric (thermal mass)
Measuring range: 0 – 5 m/s to 0 – 50 m/s, fully adjustable
Options: high temperature (3205.30)
Supply voltage: 18 – 30 VDC

 

 

LET US START SOMETHING NEW
SAY HI!

Contact: Managing Director

Colin Cook
E-post: colin@metron.as
Tel: +47 48 35 23 49